Table14.Methodsforviewingeventlogs
ConditionAction
Theserverisnothungandisconnectedtoanetwork
(usinganoperatingsystemcontrollednetworkports).
Useanyofthefollowingmethods:
•RunDSAPortabletoviewthediagnosticeventlog
(requiresIPMIdriver)orcreateanoutputfilethatyou
cansendtoLenovoserviceandsupport(usingftpor
localcopy).
•UseIPMItooltoviewthesystem-eventlog(requires
IPMIdriver).
•UsethewebbrowserinterfacetotheIMM2toview
thesystem-eventloglocally(requiresRNDISUSBLAN
driver).
Theserverisnothungandisnotconnectedtoanetwork
(usinganoperatingsystemcontrollednetworkports).
•RunDSAPortabletoviewthediagnosticeventlog
(requiresIPMIdriver)orcreateanoutputfilethatyou
cansendtoLenovoserviceandsupport(usingftpor
localcopy).
•UseIPMItooltoviewthesystem-eventlog(requires
IPMIdriver).
•UsethewebbrowserinterfacetotheIMM2toview
thesystem-eventloglocally(requiresRNDISUSBLAN
driver).
TheserverisnothungandtheIntegratedManagement
ModuleII(IMM2)isconnectedtoanetwork.
Inawebbrowser,typetheIPaddressfortheIMM2
andgototheEventLogpage.Formoreinformation,
see“ObtainingtheIMM2hostname”onpage115
and
“Loggingontothewebinterface”onpage116
.
Theserverishung,andnocommunicationcanbemade
withtheIMM2.
•IfDSAPrebootisinstalled,restarttheserverandpress
F2tostartDSAPrebootandviewtheeventlogs(see
“RunningDSAPrebootdiagnosticprograms”onpage
145
formoreinformation).
•Alternatively,youcanrestarttheserverandpressF1to
starttheSetuputilityandviewthePOSTeventlogor
system-eventlog.Formoreinformation,see“Viewing
eventlogsthroughtheSetuputility”onpage142.
Clearingtheeventlogs
Usethisinformationtocleartheeventlogs.
Tocleartheeventlogs,completethefollowingsteps.
Note:ThePOSTerrorlogisautomaticallyclearedeachtimetheserverisrestarted.
Step1.Turnontheserver.
Step2.Whentheprompt<F1>Setupisdisplayed,pressF1.Ifyouhavesetbothapower-onpassword
andanadministratorpassword,youmusttypetheadministratorpasswordtoviewtheeventlogs.
Step3.TocleartheIMM2system-eventlog,selectSystemEventLogs➙ClearSystemEventLog,
then,pressEntertwice.
POST
Whenyouturnontheserver,itperformsaseriesofteststochecktheoperationoftheservercomponents
andsomeoptionaldevicesintheserver.Thisseriesoftestsiscalledthepower-onself-test,orPOST.
Note:Thisserverdoesnotusebeepcodesforserverstatus.
Chapter4.Troubleshooting143