Table27.Powerproblemsandactions(continued)
SymptomAction
operatorinformationpanelare
notlit.
RAID/storageadapterproblems
•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
•Ifanactionstepisprecededby'(Trainedtechnicianonly)',thatstepmustbeperformedonlybyaTrained
technician.
•GototheIBMsupportwebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,
hints,tips,andnewdevicedriversortosubmitarequestforinformation.
Table28.RAID/storageadapterproblemsandactions
SymptomAction
Thesoftware
NMI/PCIerror
ledislitwhen
theHDDs/CPU/
Memoryare
stressedorduring
installationofOS.
1.CheckifyourCPU'spartnumberisinthefollowinglist:
•00D0048-Microprocessor,IntelXeonIvyBridge-EP,2.4GHz,30MB,1866MHz,115W
•00D0049-Microprocessor,IntelXeonIvyBridge-EP,2.7GHz,30MB,1866MHz,130W
•40X7385-Microprocessor,IntelXeonIvyBridge-EP,1.8GHz,10MB,1333MHz,80W
•40X7386-Microprocessor,IntelXeonIvyBridge-EP,2.5GHz,10MB,1333MHz,80W
•40X7387-Microprocessor,IntelXeonIvyBridge-EP,2.1GHz,15MB,1600MHz,80W
•40X7388-Microprocessor,IntelXeonIvyBridge-EP,2.6GHz,15MB,1600MHz,80W
•40X7389-Microprocessor,IntelXeonIvyBridge-EP,2.0GHz,20MB,1600MHz,95W
•40X7390-Microprocessor,IntelXeonIvyBridge-EP,2.6GHz,20MB,1866MHz,95W
•40X7391-Microprocessor,IntelXeonIvyBridge-EP,2.2GHz,25MB,1866MHz,95W
•40X7392-Microprocessor,IntelXeonIvyBridge-EP,2.5GHz,25MB,1866MHz,115W
•40X7393-Microprocessor,IntelXeonIvyBridge-EP,2.8GHz,25MB,1866MHz,115W
•40X7394-Microprocessor,IntelXeonIvyBridge-EP,3.0GHz,25MB,1866MHz,130W
•40X7396-Microprocessor,IntelXeonIvyBridge-EP,3.5GHz,15MB,1866MHz,130W
•40X7397-Microprocessor,IntelXeonIvyBridge-EP,3.5GHz,25MB,1866MHz,130W
•40X7398-Microprocessor,IntelXeonIvyBridge-EP,3.3GHz,25MB,1866MHz,130W
•40X7399-Microprocessor,IntelXeonIvyBridge-EP,2.4GHz,15MB,1600MHz,60W
•40X7400-Microprocessor,IntelXeonIvyBridge-EP,1.7GHz,25MB,1600MHz,70W
•40X7436-Microprocessor,IntelXeonIvyBridge-EP,1.9GHz,20MB,1600MHz,70W
•40X7438-Microprocessor,IntelXeonIvyBridge-EP,1.9GHz,25MB,1866MHz,70W
2.Ifyes,checkthetypeoftheRAIDadapter.IftheRAIDadaptertypeisM1115,thenthe
maximumnumberofM1115is"1"andisonlyavailableinslot1.
3.PoweroffthesystemandremovetheinvalidM1115RAIDadapter.
4.ReinstalltheM1115RAIDadapterinthecorrectslotandrestarttheserver.
Serialportproblems
•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
Chapter4.Troubleshooting157