Step2.LocatetheServeRAIDadapterwhichyouwillinstallthememorymodule.RemovetheServeRAID
adapterifnecessary.
Step3.Touchthestatic-protectivepackagethatcontainsthememorycardtoanyunpaintedmetalsurface
ontheserver;then,removethememorycardfromthepackage.
Step4.AlignthememorymodulewiththeconnectorontheServeRAIDadapterandpushitintothe
connectoruntilitisfirmlyseated.
Figure51.Alignthememorymodule
Ifyouhaveotherdevicestoinstallorremove,dosonow.
InstallingaRAIDadapterbatteryorflashpowermoduleremotelyin
theserver
UsethisinformationtoinstallaRAIDadapterbatteryorflashpowermoduleremotelyintheserver.
Note:WhenyouinstallanyRAIDadapterthatcomeswithbatteries,itissometimesnecessarytoinstallthe
batteriesinanotherlocationintheservertopreventthebatteriesfromoverheating.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage35.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
ToinstallaRAIDadapterbatteryorflashpowermoduleremotelyintheserver,completethefollowingsteps.
Step1.Unlockandremovetheleft-sidecover(see“Removingtheleft-sidecover”onpage40).
Step2.InstalltheServeRAIDadapteronthesystemboard(see“Installinganadapter”onpage216).
Step3.Connectoneendofthebattery/flashpowermodulecabletothebattery/flashpowermodule
connector.
Step4.Routetheremotebattery/flashpowermodulecableasshowninthefollowingillustration.
Chapter2.Installingoptionaldevices75