Step6.Reinstalltheservercover;then,reconnectallpowercords.
Step7.Restarttheserver.Thesystembeginsthepower-onself-test(POST).
Step8.Boottheservertoanoperatingsystemthatissupportedbythefirmwareupdatepackagethat
youdownloaded.
Step9.Performthefirmwareupdatebyfollowingtheinstructionsthatareinthefirmwareupdatepackage
readmefile.
Step10.Turnofftheserveranddisconnectallpowercordsandexternalcables,andthenremovethe
left-sidecover(see“Removingtheleft-sidecover”onpage40
).
Step11.ChangethepositionoftheUEFIbootbackupswitchback(changeswitch1oftheSW4totheoff
position).
Step12.Reinstalltheleft-sidecover(see“Installingtheleft-sidecover”onpage185).
Step13.Reconnectthepowercordandanycablesthatyouremoved.
Step14.Restarttheserver.Thesystembeginsthepower-onself-test(POST).Ifthisdoesnotrecoverthe
primarybank,continuewiththefollowingsteps.
Step15.Removetheleft-sidecover(see“Removingtheleft-sidecover”onpage40).
Step16.ResettheCMOSbyremovingthesystembattery(see“Removingthesystembattery”onpage233).
Step17.Leavethesystembatteryoutoftheserverforapproximately5to15minutes.
Step18.Reinstallthesystembattery(see“Installingthesystembattery”onpage235).
Step19.Reinstalltheleft-sidecover(see“Installingtheleft-sidecover”onpage185).
Step20.Reconnectthepowercordandanycablesthatyouremoved.
Step21.Restarttheserver.Thesystembeginsthepower-onself-test(POST).
Step22.Iftheserecoveryeffortsfail,contactyourLenovoservicerepresentativeforsupport.
In-bandautomatedbootrecoverymethod
Thissectiondetailsthein-bandautomatedbootrecoverymethod.
Note:UsethismethodiftheSystemboardLEDonthelightpathdiagnosticspanelislitandthereisalog
entryorBootingBackupImageisdisplayedonthefirmwaresplashscreen;otherwise,usethein-band
manualrecoverymethod.
Step1.Boottheservertoanoperatingsystemthatissupportedbythefirmwareupdatepackagethat
youdownloaded.
Step2.Performthefirmwareupdatebyfollowingtheinstructionsthatareinthefirmwareupdatepackage
readmefile.
Step3.Restarttheserver.
Step4.Atthefirmwaresplashscreen,pressF3whenpromptedtorestoretotheprimarybank.The
serverbootsfromtheprimarybank.
Out-of-bandmethod
SeetheIMM2documentation(IntegratedManagementModuleIIUser'sGuide)at
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=migr-5086346.
Automatedbootrecovery(ABR)
UsethisinformationforAutomatedbootrecovery(ABR).