Table21.Keyboard,mouse,orUSB-device'ssymptomsandactions(continued)
SymptomAction
4.Replacethekeyboard.
ThemouseorUSB-device
doesnotwork.
1.Makesurethat:
ThemouseorUSBdevicecableissecurelyconnectedtotheserver.
ThemouseorUSBdevicedriversareinstalledcorrectly.
Theserverandthemonitorareturnedon.
ThemouseoptionisenabledintheSetuputility.
2.IfyouareusingaUSBmouseorUSBdeviceanditisconnectedtoaUSB
hub,disconnectthemouseorUSBdevicefromthehubandconnectitdirectly
totheserver.
3.ReplacethemouseorUSB-device.
Memoryproblems
FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
Ifanactionstepisprecededby'(Trainedtechnicianonly)',thatstepmustbeperformedonlybyaTrained
technician.
GototheIBMsupportwebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,
hints,tips,andnewdevicedriversortosubmitarequestforinformation.
Table22.Memoryproblemsandactions
SymptomAction
Theamountofsystemmemory
thatisdisplayedislessthan
theamountofinstalledphysical
memory.
Note:EachtimeyouinstallorremoveaDIMM,youmustdisconnecttheserverfrom
thepowersource;then,wait10secondsbeforerestartingtheserver.
1.Makesurethat:
NoerrorLEDsarelitontheoperatorinformationpanel.
NoDIMMerrorLEDsarelitonthesystemboard.
Memorymirroredchanneldoesnotaccountforthediscrepancy.
Thememorymodulesareseatedcorrectly.
Youhaveinstalledthecorrecttypeofmemory.
Ifyouchangedthememory,youupdatedthememoryconfigurationinthe
Setuputility.
Allbanksofmemoryareenabled.Theservermighthaveautomatically
disabledamemorybankwhenitdetectedaproblem,oramemorybank
mighthavebeenmanuallydisabled.
Thereisnomemorymismatchwhentheserverisattheminimummemory
configuration.
2.ReseattheDIMMs,andthenrestarttheserver.
3.CheckthePOSTerrorlog:
IfaDIMMwasdisabledbyasystems-managementinterrupt(SMI),replace
theDIMM.
IfaDIMMwasdisabledbytheuserorbyPOST,reseattheDIMM;then,run
theSetuputilityandenabletheDIMM.
4.CheckthatallDIMMsareinitializedintheSetuputility;then,runmemory
diagnostics(see“RunningDSAPrebootdiagnosticprograms”onpage145).