•Avoidtouchingthecomponentsandgold-edgeconnectorsontheadapter.
•TheserverusesarotationalinterrupttechniquetoconfigurePCIadapterssothatyoucaninstallPCI
adaptersthatdonotsupportsharingofPCIinterrupts.
•ThefollowingtableliststheoptionpartnumbersandCRUpartnumbersforthenetworkadapters.
Table8.Networkadapters
Networkadaptersdescription
Optionpart
number
CRUpart
number
NetXtremeII1000expressEthernetadapter39Y606639Y6070
NetXtremeII1000expressdual-portEthernetadapter
42C1780
49Y7947
QLogic10GbCNA42C180042C1802
QLogic8GbFCdual-portHBA
42D051042D0516
NetXtremeII1000expressquad-portEthernetadapter49Y422049Y7949
IntelEthernetdual-portserveradapterI340-T249Y423049Y4232
IntelEthernetquad-portserveradapterI340-T449Y424049Y4242
BroadcomNetXtremeIIdual-port10GBaseTadapter
49Y791049Y7912
IntelX520-DA2dual-port10GbESFPadapter
49Y796049Y7962
IntelX540-T2dual-port10GBaseTadapter
49Y797049Y7972
BroadcomNetXtremeIquad-portGbEadapter
90Y935290Y9355
BroadcomNetXtremeIdual-portGbEadapter
90Y937090Y9373
Emulex10GbEvirtualfabricadapterIII
95Y37629573766
Emulex10GbEvirtualfabricadapterIIIlite
95Y376895Y3766
Attention:Staticelectricitythatisreleasedtointernalservercomponentswhentheserverispowered-on
mightcausetheservertostop,whichmightresultinthelossofdata.Toavoidthispotentialproblem,
alwaysuseanelectrostatic-dischargewriststraporothergroundingsystemwhenworkinginsidethe
serverwiththepoweron.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage35.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
Toinstallanadapter,completethefollowingsteps.
Step1.Carefullyturntheserveronitssidesothatitislyingflat,withthecoverfacingup.
Attention:Donotallowtheservertofallover.
Step2.Unlockandremovetheleft-sidecover(see“Removingtheleft-sidecover”onpage40).
Step3.Seethedocumentationthatcomeswiththeadapterforanycablinginstructionsandinformation
aboutjumperorswitchsettings.(Itmightbeeasierforyoutoroutecablesbeforeyouinstall
theadapter.)
Step4.Touchthestatic-protectivepackagethatcontainstheadaptertoanyunpaintedmetalsurfaceon
theserver;then,removetheadapterfromthepackage.
Step5.DeterminethePCIslotintowhichyouwillinstalltheadapter.
Step6.Rotatetheadapter-retentionbracketstotheopenposition.
Chapter2.Installingoptionaldevices71