EasyManua.ls Logo

Lenovo System x3500 M4 - Page 984

Lenovo System x3500 M4
1182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UserResponse
Completethefollowingsteps:
1.VerifythatmatchingProcessorsareinstalledinthecorrectProcessorsocketsaccordingtothe
serviceinformationforthisproduct.
2.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thisProcessorerror.
3.(TrainedServicetechnicianonly)Replacethesystemboard.
I.2018002[I.2018002]ThedevicefoundatBus%Device%Function%couldnotbeconfigured
duetoresourceconstraints.TheVendorIDforthedeviceis%andtheDeviceIDis%.
Explanation:OUT_OF_RESOURCES(PCIOptionROM)
Severity
Info
UserResponse
Completethefollowingsteps:
1.IfthisPCIedeviceand/oranyattachedcableswererecentlyinstalled,moved,servicedor
upgraded,reseatadapterandanyattachedcables.
2.CheckIBMsupportsiteforanyapplicableservicebulletinorUEFIoradapterfirmwareupdate
thatappliestothiserror.NOTE:ItmaybenecessarytodisableunusedoptionROMsfromUEFI
F1setuporASUorusingadaptermanufacturerutilitiessothatadapterfirmwarecanbeupdated.
3.Movecardtoadifferentslot.Ifslotnotavailableorerrorre-occurs,replaceadapter.
4.(TrainedServicetechnicianonly)Ifadapterwasmovedtoadifferentslotanderrordidnot
re-occur,verifythatthisisnotasystemlimitationandthenreplacethesystemboard.Also,if
thisisnottheinitialinstallationandtheerrorpersistsafteradapterreplacement,replacesystem
board.
I.2018003[I.2018003]AbadoptionROMchecksumwasdetectedforthedevicefoundatBus%
Device%Function%.TheVendorIDforthedeviceis%andtheDeviceIDis%.
Explanation:ROMCHECKSUMERROR
Severity
Error
UserResponse
Completethefollowingsteps:
1.IfthisPCIedeviceand/oranyattachedcableswererecentlyinstalled,moved,servicedor
upgraded,reseatadapterandanyattachedcables.
2.Moveadaptertoadifferentsystemslot,ifavailable.
3.CheckIBMsupportsiteforanyapplicableservicebulletinorUEFIoradapterfirmwareupdate
thatappliestothiserror.NOTE:ItmaybenecessarytoconfigureslottoGen1ortouse
specialutilitysoftwaresothatadapterfirmwarecanbeupgraded.Gen1/Gen2settingscanbe
configuredviaF1Setup->SystemSettings->DevicesandI/OPorts->PCIeGen1/Gen2/Gen3
SpeedSelection,ortheASUUtility.
4.Replaceadapter.
970Systemx3500M4InstallationandServiceGuide