1.Checkthesystem-eventlogforuncorrectedDIMMfailuresandreplacethoseDIMMs.
I.580A6[I.580A6]Memorysparecopyhascompletedsuccessfully.
Explanation:SpareCopyComplete
Severity
Info
UserResponse
Completethefollowingsteps:
1.ChecksystemlogforrelatedDIMMfailuresandreplacethoseDIMMs.
S.1100B[S.1100B]CATERR(IERR)hasassertedonprocessor%.
Explanation:ProcessorCATERR(IERR)hasasserted
Severity
Error
UserResponse
Completethefollowingsteps:
1.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thisProcessorerror.
2.(TrainedServicetechnicianonly)ReplacetheProcessor.
S.1100C[S.1100C]Anuncorrectableerrorhasbeendetectedonprocessor%.
Explanation:Uncorrectableprocessorerrordetected
Severity
Error
UserResponse
Completethefollowingsteps:
1.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thiserror.
2.Rebootsystem.Ifproblempersistsescalatetothenextlevelofsupprt.
S.2011001[S.2011001]AnUncorrectedPCIeErrorhasOccurredatBus%Device%Function%.
TheVendorIDforthedeviceis%andtheDeviceIDis%.
Explanation:PCISERRDetected
Severity
Error
UserResponse
Completethefollowingsteps:
1.Ifthisnodeand/oranyattachedcableswererecentlyinstalled,moved,servicedorupgraded,a.
ReseatAdapterandanyattachedcables.b.ReloadDeviceDriverc.Ifdeviceisnotrecognized,
AppendixB.UEFI(POST)errorcodes973