3.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thiserror.
4.ReflashUEFIFirmware.
5.(Trainedservicetechnicianonly)Replacethesystemboard.
•W.3808002[W.3808002]AnerroroccurredwhilesavingUEFIsettingstotheIMM.
Explanation:ErrorUpdatingSystemConfigurationtoIMM
Severity
Warning
UserResponse
Completethefollowingsteps:
1.UseF1Setup,VerifySettingsandSaveSettingstorecoversettings.
2.ResettheIMMfromtheCMM.
3.UseCMMtoremoveAUXpowerfromthenode.Thiswillreboottheentirenode.
4.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thiserror.
5.ReflashIMMFirmware.
6.Removeandre-installCMOSbatteryfor30secondstoclearCMOScontents.
7.TrainedServicetechnicianonly)Replacethesystemboard.
•W.3808003.[W.3808003]UnabletoretrievethesystemconfigurationfromtheIMM.
Explanation:ErrorRetrievingSystemConfigurationfromIMM
Severity
Warning
UserResponse
Completethefollowingsteps:
1.UseF1Setup,VerifySettingsandSaveSettingstorecoversettings.
2.ResettheIMMfromtheCMM.
3.UseCMMtoremoveAUXpowerfromthenode.Thiswillreboottheentirenode.
4.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thiserror.
5.ReflashIMMFirmware.
6.Removeandre-installCMOSbatteryfor30secondstoclearCMOScontents.
7.TrainedServicetechnicianonly)Replacethesystemboard.
•W.3818005[W.3818005]TheCRTMflashdrivercouldnotsuccessfullyflashthestagingarea.The
updatewasaborted
Explanation:CRTMUpdateAborted
Severity
984Systemx3500M4InstallationandServiceGuide