Start-up
- 49 -10.13
13.5 Deactivate operation mode
The operation mode spot welding and inter-
val can be deactivated in the menu and will
no longer be accessable with mode key 47.
 Press key menu 48.
 Set menu to „options“ by turning operation
knob 52.
 Conrm menu „options” by pressing op-
eration knob 52.
 Set the menu option „interval welding“ or
„spot welding“ by turning operation knob
52 for deactivation.
 Conrm the menu option by pressing opera-
tion knob 52.
 Select and conrm the menu option „off“
by using operation knob 52.
Abb. 19: Interval-welding deactivated
 Press key 46, 50 or 51 to end menu and
return to standard display.
13.6 Characteristic line
Select characteristic line
 Press key menu 48.
 Set menu option „characteristic line“ by
turning opertion knob 52.
 Conrm menu option „characteristic line“
by pressing operation knob 52.
 Set required characteristic line by turning
operation knob 52.
 Conrm characteristic line by pressing op-
eration knob 52.
Abb. 20: Characteristics
 Press key 46, 50 or 51 to exit menu and
return to standard display.
9 If the graphic display shows „noP“ (no pro-
gram) for material thickness, the set weld-
ing step is inapplicable for the selected
characteristic line.
Abb. 21: „noP“ (no program)
 Select a suitable welding step with turning
knob 45.