Messages
- 58 - 10.13
In case of failure, a failure code is displayed
in graphical display 49.
As long as there is an error code
on display welding is not possible.
15 Messages
Code Error description Note Rectication
noP no program Instead of material thickness „noP”
is displayed.
Welding is not possible at activated
characteristic line and set welding
step.
Select a different weld-
ing step
E01 Excessive tempera-
ture
The equipment has been over-
heated
Allow the system to cool
down in standby, check
the ventilation system
E02 Mains overvoltage Mains input voltage too high Check mains voltage
E03 Overcurrent Output current is too high / Perma-
nent short circuit
Inform Service
E06 Overvoltage Output voltage too high Inform Service
E07 EEProm checksum
error
Setting data faulty or missing Switch the equipment
off and on again
E08 Wire feed Too high power intake from wire
feed motor (Motor Over-Current)
Blow down torch pack-
age with pressured air
and check pressure on
wire feed rolls.
E09 Voltage-measuring Voltage measuring system defective Inform Service
E10 Torch connector/-
cable
Welding potential on torch control
cable
Check torch/exchange
E13 Temp. sensor error Thermal sensor not ready for opera-
tion
Inform Service
E14 Supply voltage internal supply voltage too low
(18V~ / 24V-)
Check mains voltages
E15 Power measuring Fault at power measuring Inform Service