Chapter 8 EMC Standard Certification
Chapter 8 EMC Standard Certification
8.1
Requirement for EMC Standard Certification
EMC command is regulated on “It doesn’t produce the Strong electromagnetic waves: Emission” and “It is not
affected by electromagnetic wave from external: Immunity”. The following is describing the contents to meet the
EMC command when configuring the system by using the XGT Panel. This is a summary document for the
request and standard which our company has obtained from EMC but we don't assure that all devices
manufactured according to these contents are not suitable for the below standards. The final manufacturer needs
to finally judge about the fitness method or fitness judgment of EMC command.
8.1.1
CE Standard Certification
In case of XGT Panel, the EN61000-6-4, EN61000-6-2, EN61000-3-2, and EN61000-3-3 of CE standards were
applied.
Applied Standards Results
EN61000-6-4:2007 / A1 : 2011
EN61000-6-4:2007 / A1 : 2011
Harmonic Current Emission
Voltage Change, Fluctuations and Flicker
Electrostatic Discharge
EN61000-6-2:2005 / AC : 2005
C
Radio-Frequency Electromagnetic Field
EN61000-6-2:2005 / AC : 2005
C
EN61000-4-3:2006 / A1 : 2008 / A2 : 2010
Fast Transient
EN61000-6-2:2005 / AC : 2005
C
EN61000-4-4:2004 / A1 : 2010
Radio-Frequency Continuous Conducted
EN61000-6-2:2005 / AC : 2005
C
Power-Frequency Magnetic Fields
EN61000-6-2:2005 / AC : 2005
N/T
Surges
EN61000-6-2:2005 / AC : 2005
C
Voltage Dips and Interruptions
EN61000-6-2:2005 / AC : 2005
N/T
EN61000-4-11:2004
C=Comply NC=Not Comply N/T=Not Tested N/A=Not Applicable