Ultrasound Platform
SERVICE MANUAL
FEBRUARY 2020 A/S/B Scan & UBM
11, rue du bois joli - CS 40015
63808 Cournon d’Auvergne Cedex
FRANCE
Tel.: +33 (0) 473 745 745
Fax: +33 (0) 473 745 700
E-mail: contact@quantel-medical.fr
Web site: www.quantel-medical.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lumibird Quantel ABSOLU and is the answer not in the manual?

Summary

INTRODUCTION

USER MANUAL TERMS AND SAFETY SYMBOLS

WARNINGS & CAUTIONS

Servicing the Unit Warnings and Cautions

Guidelines and warnings specific to servicing the ABSOLU unit, including warranty void conditions.

Using the Unit Warnings and Cautions

Safety precautions and warnings for operating the ABSOLU ultrasound platform during use.

Probes: Warnings and Cautions

Safety guidelines and handling precautions for ABSOLU ultrasound probes to prevent damage and ensure proper use.

Waste and Device Elimination Precautions

Procedures and precautions for the proper disposal of the ABSOLU device and its accessories according to regulations.

ABSOLU TECHNICAL SPECIFICATIONS

System Classification

Details on the ABSOLU system's classification regarding electrical safety, protection, and type.

Electrical Requirements

Specifications for the ABSOLU's power supply, frequency, and maximum power consumption.

Compliance Standards

List of standards and directives the ABSOLU system conforms to, ensuring safety and performance.

System Dimensions and Weight

Physical measurements including width, depth, height, and weight of the ABSOLU unit.

Environmental Operating Conditions

Recommended temperature, humidity, and atmospheric pressure ranges for operating and storing the ABSOLU.

Computer System Specifications

Technical details of the ABSOLU's internal computer system, including processor, memory, and storage.

ULTRASOUND SYSTEM PROBES SPECIFICATIONS

Standardized A Probe Specifications

Technical details for the ABSOLU's standardized A-mode ultrasound probe.

Biometry Probe Specifications

Specifications for the ABSOLU biometry probe, including frequency and resolution.

15 MHz B-SCAN Probe Specifications

Technical details for the 15 MHz B-mode ultrasound probe, including sector angle and resolution.

20 MHZ Annular B-SCAN Probe Specifications

Specifications for the optional 20 MHz annular B-mode ultrasound probe.

50 MHZ Linear Probe Specifications

Technical details for the 50 MHz linear ultrasound probe, including frequency and resolution.

BLOCK DIAGRAM

MAIN UNIT AND ACCESSORIES

Main Units, Probes, and Options

Overview of the primary ABSOLU system configurations, included probes, and available options.

Accessories and Consumables

List of accessories and consumable items required or recommended for the ABSOLU unit.

Spare Parts Identification

Identification codes and descriptions for essential spare parts of the ABSOLU system.

Footswitch Operation

Description of the functions and operation of the single and ABSwitch footswitches for ABSOLU.

DISASSEMBLING THE UNIT FOR SPARE PARTS REPLACEMENT

Removing the Main Back Cover

Step-by-step instructions for safely removing the back cover of the ABSOLU unit.

Accessing Subsystem Boards

Procedures for accessing the internal subsystem boards within the ABSOLU unit.

Replacing A-15-50 ERM Board with S-15-50 ERM Board

Specific instructions for replacing an A-15-50 ERM board with an S-15-50 ERM board.

Removing the Screen from the Base

Detailed steps to safely detach the display screen from the main base of the ABSOLU device.

Opening the Display Screen Assembly

Instructions on how to open the ABSOLU unit's display screen assembly to access internal components.

Removing the Power Supply Unit

Procedure for safely removing the power supply module from the ABSOLU unit.

Fuse Replacement Procedure

Guidelines for replacing fuses in the ABSOLU unit, including fuse specifications.

ABSOLU DEVICE DISPLAY - MAGNIFIER TOOL ADJUSTMENT

PROBES MANAGEMENT AND CALIBRATION

Standardized (A-Std); Regular Biometry (A) Probe

Management and calibration procedures for standardized and regular biometry A-type probes.

Adding;Removing Biometry Probes & Calibration

Steps for adding or removing biometry probes and performing the necessary calibration.

Deleting or Adding Biometry Probes

Instructions on how to delete existing or add new standardized/regular biometry probes.

Tissue Sensitivity Determination for A-Std Probes

Procedure for determining tissue sensitivity for A-Std probes when the S mode is activated.

Biometry Probe Calibration Test

Procedure for testing and calibrating regular biometry probes using the ABSOLU test block.

Biometry Probe Calibration Procedure

Detailed steps for calibrating regular biometry probes, ensuring accurate measurements.

Managing Other Probes (B15, B20-5 A, LIN50 MHz)

Instructions for adding or removing B15, B20-5A, and LIN50MHz probes from the system.

Linear Probe Calibration Check

Procedure for systematically checking the calibration of linear probes for accurate sizing.

Calibration Tool Description

Information about the calibration tool provided for linear probes and its markings.

Calibration Setup for Linear Probes

Steps and requirements for setting up the calibration process for linear probes.

LIN 50 Probe Calibration Procedure

Step-by-step guide to perform the calibration procedure for the LIN 50 MHz probe.

Checking B20-5 A Probe Ring Images

Solving Noise Problems with B and Linear Probes

Linear Probes Care and Storage

DATABASE MANAGEMENT

Data Information Structure

Overview of the ABSOLU database structure, including folder organization and data types.

Saving the ABSOLU Database

Procedures for saving the ABSOLU database, including options for saving data only or the entire database.

Saving Database Only (Without Data)

Steps to save only the database files, excluding patient data like images and Cineloop.

Saving Data Only (Images, Cineloop)

Procedure to save only patient data such as images and Cineloop recordings.

Saving All Data (Database + Data)

Instructions for backing up both the database and all associated patient data.

Database Factory Installation

Steps to install the factory default database, which resets the system.

Procedure to Install the Database Factory

Step-by-step guide for installing the ABSOLU factory database from a zip file.

Calibration of A-Bio and A-ProBeam Probes

Calibration procedures for the A-Bio and A-ProBeam probes after installation.

Transferring Database from Master to Destination ABSolu

Procedure for transferring the database from a master to a destination ABSolu system.

Backup of the Master ABSolu Database

Steps to create a backup of the master ABSOLU database for transfer.

Import Master ABSolu Database to Destination ABSolu

Procedure to import the master ABSOLU database into a destination ABSOLU system.

Calibration of A-Bio and A-ProBeam Probes (Post-Transfer)

Recalibration steps for A-Bio and A-ProBeam probes after database transfer.

SOFTWARE UPDATE PROCEDURE

Procedure to Install New Software

Instructions for updating the ABSOLU software to the latest version.

UPGRADING THE INTEL GRAPHICS DRIVER

Checking Intel HD Graphics 520 Driver Version

Steps to verify the current driver version for Intel HD Graphics 520.

Installing the Recommended Driver Version

Procedure for installing the correct Intel HD Graphics 520 driver version for ABSolu compatibility.

Suspending Automatic Driver Updates

How to disable automatic Windows driver updates to maintain specific versions.

COBIAN APPLICATION INSTALLATION

ABSOLU SETUP AND CONFIGURATION

Retina Slope Test Setting

Configuration of the Retina Slope Test parameter for optimal A-scan sharpness.

Contact Information Display

Accessing Quantel Medical contact details within the ABSolu setup menu.

Activate Threshold Line for LESION Q-I

Enabling or disabling the threshold line for LESION Q-I in the ABSolu setup.

Activate Axial Length Measurement

Enabling the Axial Length measurement feature in the ABSOLU setup.

HIPAA COMPLIANCE MEASURES

Security Awareness and Training

HIPAA requirements for security training and awareness for personnel handling patient data.

Contingency Plan for Data Protection

HIPAA requirements for data backup and disaster recovery plans.

Access Control Procedures

HIPAA requirements for managing user access and emergency access procedures.

Audit Controls Implementation

HIPAA requirements for implementing audit controls to monitor system activities.

Data Integrity Mechanisms

HIPAA requirements for ensuring the integrity of electronic protected health information.

Person;Entity Authentication

HIPAA requirements for verifying the identity of users accessing patient data.

Transmission Security Measures

HIPAA requirements for securing transmitted electronic health information.

Lumibird Quantel ABSOLU Specifications