Page #29 background image
Lynx NGT-9000s
Installation Manual
Table 1-3: Specifications for Lynx NGT-9000s
OPERATING TEMPERATURE:
-20° to +55°C (-4° to +131°F)
STORAGE TEMPERATURE:
-55° to +85°C (-67° to +185°F)
MAXIMUM ALTITUDE:
55,000 ft (installation environment)
FUNCTIONALITY:
Mode S Transponder
Global Positioning System (GPS)
UAT/1090ES ADS-B In
1090ES ADS-B Out: Automatic Dependent Surveillance Broadcast
Traffic Awareness System (TAS) (optional)
OPERATION:
Start Up Time: On Ground 20 seconds or less
In air 5 seconds or less.
Display Luminance: Range 0.05 fl to 150 fl
Built In Test: Fault Monitoring on all stages of operation from start up to
power down.
UAT Receiver Sensitivity
(Class A1S)
-95.0dBm for 90% Message Decoding for Long ADS-B
Messages
-96.0dBm for 90% Message Decoding for Short ADS-B
Messages
-93.0dBm for 90% Message Decoding for Ground Uplink
Messages
Mode S Transponder Power (Class 1 Transponder). 125W minimum, 250 W maximum.
TAS Output Power (Class A TAS). 125W minimum, 250 W maximum.
SCHEDULED MAINTENANCE:
The Lynx NGT-9000s is a transponder device and must be tested and inspected every 24
months subject to the requirements of FAA documents 14 CFR Part 43 Appendix F.
SERVICE LIFE:
The Lynx NGT-9000s has unlimited service life.
REPAIRABILITY:
Repairs performed at the FAA certificated Repair Station co-located at the OEM
(equipment) facility.
0040-17001-01 General Information Page 1-13
Revision A January 15, 2015

Table of Contents

Other manuals for Lynx NGT-9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lynx NGT-9000 and is the answer not in the manual?

Lynx NGT-9000 Specifications

General IconGeneral
BrandLynx
ModelNGT-9000
CategorySecurity System
LanguageEnglish

Related product manuals