Catch Sensors | V1 | Servicing and Maintenance
Procedure
1.
To remove the housing of the sensor: remove the screws on each side of the end cap
using a size 6 Allen key, then push the bottle out.
2.
Remove the retainer ring around the transducer (yellow part).
3.
To remove the black tube around the bottle, place the bottle in a vise or on the ground
and pull out the black tube.
You have now access to the electronic components.
4.
Remove the tape protecting the components.
5.
Disconnect the battery from the PCBA.