Catch Sensors | V1 | Servicing and Maintenance
23.
Put back the housing around the bottle. The circle on the transducer must be on
the side of the housing that has no "UP" writing, and must be aligned to the round
opening in the housing.
Replacing the Temperature Sensor
Before you begin
For this task you need the following tools:
• 6 mm Allen key
• 1.5 mm Allen key
• 1/8" Allen key
• 22 mm wrench
• Tweezers
• Wire stripper
• Crimping tool
• O-ring lubricant
• Loctite 425
About this task
Only qualified Marport technicians can do this task.
| 72