EasyManua.ls Logo

Matrix mvBlueFOX3 - Page 1472

Matrix mvBlueFOX3
1974 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
reception of a trigger
before starting the Timer.
(us)
TimerValue 0.000 UINT_MAX - -
Reads or writes the
current value (in
microseconds) of the
selected Timer. (us)
TimerReset@i - - - -
Does a software reset of
the selected timer and
starts it. The timer starts
immediately after the
reset unless a timer
trigger is active.
Feature Name Min Max Inc
Valid
Values
Documentation
AnalogControl
A category that contains
the Analog control
features.
mvTapBalancingMode - - -
mvFactory,
mvUser
States where the tap
balancing calibration data
does come from
mvFactory: States where
the tap balancing
calibration data does
come from
mvUser: States where the
tap balancing calibration
data does come from
GainSelector - - -
AnalogAll,
DigitalAll
Selects which Gain is
controlled by the various
Gain features.
AnalogAll: Gain will be
applied to all analog
channels or taps.
DigitalAll: Gain will be
applied to all digital
channels or taps.
Gain 0.000 18.000 - -
Controls the selected gain
as an absolute physical
value in dB. This is an
amplification factor
applied to the video
signal. (dB)
GainAuto - - - Off,
Continuous
Sets the automatic gain
control (AGC) mode. The
exact algorithm used to
implement AGC is
21 Appendix A.2 CMOS specific camera / sensor data
1464