Feature Name Min Max Inc
Valid
Values
Documentation
AnalogControl
A category that contains
the Analog control
features.
mvTapBalancingMode - - -
mvFactory,
mvUser
States where the tap
balancing calibration
data does come from
mvFactory: States
where the tap balancing
calibration data does
come from
mvUser: States where
the tap balancing
calibration data does
come from
GainSelector - - -
AnalogAll,
DigitalAll,
DigitalTap1,
DigitalTap2,
DigitalTap3,
DigitalTap4
Selects which Gain is
controlled by the various
Gain features.
AnalogAll: Gain will be
applied to all analog
channels or taps.
DigitalAll: Gain will be
applied to all digital
channels or taps.
DigitalTap1: Digital gain
will be applied to Tap 1.
DigitalTap2: Digital gain
will be applied to Tap 2.
DigitalTap3: Digital gain
will be applied to Tap 3.
DigitalTap4: Digital gain
will be applied to Tap 4.
Gain 0.000 48.000 - -
Controls the selected
gain as an absolute
physical value in dB.
This is an amplification
factor applied to the
video signal. (dB)
GainAuto - - -
Off,
Continuous
Sets the automatic gain
control (AGC) mode.
The exact algorithm
used to implement AGC
is device-specific.
Off: Gain is User
controlled using Gain.
Continuous: Gain is
constantly adjusted by
the device.
20 Appendix A.1 Pregius CMOS specific camera / sensor data
827