signal to use as internal
source for the trigger.
UserOutput3: Specifies
which User Output bit
signal to use as internal
source for the trigger.
TimerTriggerActivation - - -
RisingEdge,
FallingEdge,
AnyEdge,
LevelHigh,
LevelLow
Selects the activation
mode of the trigger to
start the Timer.
RisingEdge: Starts
counting on the Rising
Edge of the selected
trigger signal.
FallingEdge: Starts
counting on the Falling
Edge of the selected
trigger signal.
AnyEdge: Starts counting
on the Falling or Rising
Edge of the selected
trigger signal.
LevelHigh: Counts as
long as the selected
trigger signal level is
High.
LevelLow: Counts as
long as the selected
trigger signal level is
Low.
TimerDuration 0.000 UINT_MAX - -
Sets the duration (in
microseconds) of the
Timer pulse. (us)
TimerDelay 0.000 UINT_MAX - -
Sets the duration (in
microseconds) of the
delay to apply at the
reception of a trigger
before starting the Timer.
(us)
TimerValue 0.000 UINT_MAX - -
Reads or writes the
current value (in
microseconds) of the
selected Timer. (us)
TimerReset@i - - - -
Does a software reset of
the selected timer and
starts it. The timer starts
immediately after the
reset unless a timer
trigger is active.
20 Appendix A.1 Pregius CMOS specific camera / sensor data
826