STARTER - HITACHI/MITSUBISHI
Article Text (p. 2)
1983 Mazda RX7
For www.iluvmyrx7.com
Copyright © 1998 Mitchell Repair Information Company, LLC
Sunday, August 26, 2001 03:31PM
B2200 Pickup ............... 180 .......................... 3800
GLC
FWD Sedan .................. 53 .......................... 6800
RWD Wagon .................. 53 .......................... 6800
RX7
Man. Trans. ................ 60 .......................... 6500
Auto. Trans. .............. 100 .......................... 3500
626
Man. Trans. ................ 60 .......................... 6500
Auto. Trans. ............... 60 .......................... 6600
(1) - Applied voltage of 11.5-12 volts.
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Load (Lock Torque) Test
Mount starter in a test stand to perform torque measurement
test. Follow manufacturer's instructions for test stand operation.
With voltage adjusted, ammeter reading and torque should be within
specifications.
MITSUBISHI STARTER LOAD TEST SPECIFICATIONS TABLE (1)
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Max. Torque
Application Amps Volts Ft. Lbs. (N.m)
Mazda
B2000 Pickup ........ 310 ............ 5 ........... 5.4 (7.5)
B2200 Pickup ....... 1050 ............ 2 ........... 21.7 (30)
GLC
FWD ................ 310 ............ 5 ........... 5.4 (7.5)
Wagon .............. 310 ............ 5 ........... 5.4 (7.5)
RX7
Man. Trans. ........ 600 ............ 5 ........... 6.9 (9.6)
Auto. Trans. ...... 1100 ............ 4 ........... 22.4 (31)
626 ................. 310 ............ 5 ........... 5.4 (7.5)
(1) - Turning speed not specified by manufacturer.
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
SOLENOID TESTS
NOTE: Make tests with solenoid removed from starter or remove
solenoid lead to starter before testing. Ensure solenoid
plunger and sleeve are clean and dry before performing
tests. Make tests in less than 10 seconds to prevent coil
damage.
Pull-In Coil Test
1) Connect jumper between positive post of 12-volt battery
and "S" terminal. Connect a second jumper to negative battery
terminal and touch "M" (MT) terminal (and between terminal "S" and
switch body). See Fig. 1.