A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES
Article Text (p. 4)
1983 Mazda RX7
For www.iluvmyrx7.com
Copyright © 1998 Mitchell Repair Information Company, LLC
Sunday, August 26, 2001 04:42PM
Fig. 2: Evaporator Temperature/Pressure A/C Chart
AIR CONDITIONING DIAGNOSIS WITH GAUGES FOR SYSTEMS WITH
INSUFFICIENT OR NO COOLING TABLE
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Low Side High Side Other Symptoms (1) Diagnosis
Gauge Gauge
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
NORMAL NORMAL No or few bubbles in sight Some Air and
glass. High side gauge may Moisture in
go high. Low side gauge System
does not fluctuate with
compressor on/off cycle.
NORMAL NORMAL Cools okay in morning but Excessive
not during hot part of day. Moisture in
Bubbles in sight glass. System
Discharge air warm when low
side gauge drops into vacuum.
NORMAL NORMAL Thermostatic switch system Defective
only - compressor cycles off Thermostatic