COOLING SYSTEM
01–12–4
WATER PUMP CONSTRUCTION/OPERATION [LF]
E5U011215010N01
Construction
• The aluminum alloy water pump with the impeller
built into the cylinder block has been adopted for
size reduction.
• The water pump is not serviceable and must be
replaced as a unit if it has a malfunction.
Operation
• The water pump is driven by the drive belt.
End Of Sie
COOLING FAN COMPONENT CONSTRUCTION/OPERATION [LF]
E5U011215140N01
Construction
• The cooling fan component consists of the radiator cowling, cooling fan, and cooling fan motor.
• Electric cooling fan, which operates according to the fan control signal from the PCM, has been adopted. Due
to this, engine noise has been reduced and rapid engine warming-up is possible.
• The radiator cowling and cooling fan are made of plastic for weight reduction.
Cooling fan, cooling fan motor specification
Operation
• Cooling fan operates according to the engine coolant temperature and whether the A/C is on or off. Three-
stage control has been adopted to the cooling fan with high, middle, and low speed rotation allowing noise
reduction and power savings. (See 01–40–34 ELECTRICAL FAN CONTROL OPERATION [LF].)
End Of Sie
WATER PUMP PULLEY
WATER PUMP BODY
IMPELLER
C3E0112T019
Item Specification
Cooling fan
Number of blades 5
Outer diameter (mm {in}) 360 {14.2}
Cooling fan motor output (W) 120
COOLING FAN COMPONENT
COOLING FAN
COOLING FAN MOTOR
RADIATOR COWLING
E5U112ZS5006