Page 902
Revision 7
95-30-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright © 19992016 by MD Helicopters, Inc.
(3). Route TOT3A22N to the 3-Pack
instrument cluster, install lug
(MS25036-103) and attach to GND.
(4). Route TOT4A22 to TB105-4 (front of
instrument panel) and install lug
(MS25036-103).
(5). Modify existing wires from TC300 as
follows:
(a). Remove wire lug from E10A16
(chromel) wire and install socket
(M39029/32-245); insert in P5-F.
(b). Remove wire lug from E10A16
(alumel) wire and install socket
(M39029/32-244); insert in P5-G.
D. Reassembly After Indicator Installation
(1). Remove post light and fill existing hole
with an #8 panhead screw, washer and
locknut.
(2). Clean all areas of work.
(3). Reinstall instrument panel covers.