4-5
MELTER OPERATION MA-5082-ENG B4 VS ADHESIVE MELTER MANUAL
Temperature adjustment
By default, the melters have the following parameter values:
• Tank and distributor set point temperature: 160°C
• 150ºC for hoses and 160ºC for applicators
• Display in °C
• Overheating value: 20°C
• Standby value: 40%
• Delay time: 10 mins
• Time programming: ON
The general procedure for adjusting the temperature of each of the
components is described below.
1. Use the up-down arrows to select the component for which you wish to
change the value.
The corresponding LED will blink quickly.
2. Use the up-down arrows under the display to select the desired value
for the set point temperature. Below 40°C, the temperature value
displays ‘OFF’, cancelling the heating of this component (hoses and
applicators only).
3. After ten seconds the LED will stop blinking and the display will change
by default to the tank set point temperature, saving the changed data.
Repeat this simple procedure for each of the components whose set point
temperature you would like to change.
Code Cause
Actions
Heating Pump Main machine signal
Err 0 tank broken sensor only tank off off off
Err 1 hose1 broken sensor only hose1 off off off
Err 2 applicator1 broken sensor only applicator1 off off off
Err 3 hose2 broken sensor only hose2 off off off
Err 4 applicator2 broken sensor only applicator2 off off off
Err 100 tank overheating all components off off off
Err 101 hose1 overheating all components off off off
Err 102 applicator1 overheating all components off off off
Err 103 hose2 overheating all components off off off
Err 104 applicator2 overheating all components off off off
40ºC40ºC
OFFOFF