FOCKE MELER GLUING SOLUTIONS
A-8
AIRTIGHT LID
After loading new adhesive or each time that the unit’s tank cover is opened,
we recommend using the manual injection method for approximately 60 s. To
do this, activate the button on the system’s electrovalve.
To maintain the air drying system in perfect condition, we recommend
periodically observing the green indicator for filter saturation control. If this
indicator turns red, it is necessary to replace the filter cartridges. See the
corresponding chapter for replacement parts.
Filling the tank
The tank can be equipped with a low level detector that warns when the
adhesive sown to one-third of its capacity, approximately.
The unit will activate the external signal and, if it is connected, the
corresponding warning device.
Warning: Before refilling the tank, make sure that the adhesive is the same
type as that already in the tank. Mixing different types of adhesives can cause
damage to the melter equipment.
To fill the tank:
1. Open the top cover and turn the cam handle left up taking it to position
that the image shows (1).
2. Take the handle and open the lid until fix the retractable positioner (2).
3. Fill the tank with PUR adhesive block of 2 kg.
4. To close the air-tight, unlock the fixing mechanism, holding the lid with
the other hand. Turn the handle in clockwise sense to fix it.
5. Finally close the top cover.
Warning: Risk of burns. Always refill using protective gloves and glasses.