A-11
AIRTIGHT LID MA-5082-ENG B4 VS MANUAL APPENDIX
A6. TECHNICAL CHARACTERISTICS
General
Tank volume
Maximum pump flow rate (*)
Maximum melting rate (*)
Number of pumps
Number of outputs
Gear motor
Pump
Pump rotation speed
Maximum working pressure
Total equipment output
External functions
Options
Electrical requirements
Room temperature
Temperature range
Temperature control
Dimensions
Weight
(*) Under normal conditions
4 litres
between 1,2 and 15,6 Kg/hr with 2 cc/rev pump
6,0 kg/h
1
2
three-phase 179 W two-pole forced ventilation
2cc/rev
0-100 rpm (recommended 10-80 rpm continuously)
80 bar max. (1160 psi)
mechanical or pneumatic bypass valve (adjustable)
3680 W_16 A
Temperature output ok
External standby
Starting up the motor
Motor speed set point reference
Failures output in pump control card
Level control system
Air drying system for PUR adhesives
LN~ 230 V 50 Hz + PE/ 16A
0 to 40°C
40 to 200°C (100 to 392°F)
RTD ±0.5°C (±1°F) Pt100 and Ni120
see diagram on following page
51,5 kg without load (approx)