MELTER OPERATION
MICRON+ PISTÓN
10 min
Modbus
B: 57600Node: 10
85 °C 60 s
2.2 Extra Settings
Sound on alarm
Screen saver
Inside device temperature alarm
Pumping security
2.2 Extra settings
Pumping security: When this option is activated, if you want to enable the
pumping permission you have to manually press the STOP button once
the unit is in ‘Temperature OK’.
Cabinet temperature alarm: A value (+°C/°F) and a time are defined to
indicate when the alarm is activated due to overheating inside the unit’s
electrical cabinet. If it reaches this temperature and maintains it for the set
time, the unit disconnects the heating of all zones and stops the pumping.
Activate or deactivate the alarm sound. To stop the sound, press the
ALARM icon on the HOME screen.
Activate or deactivate the screensaver. The screen switches off after the
set time has passed. If you press the screen when it is off, it turns on and
the HOME menu appears.
Activate or deactivate the Modbus communication.
MICRON+ PISTÓN
6
2.2 Extra Settings
Level detector”
Channel number
Automatic charge
Pattern controller
Number of channels. Configures the number of electrical outputs
enabled in the melter.
Level sensor. Indicates whether or not the unit has a minimum adhesive
level sensor. See the point ‘Menu 3. Feeding’ for programming the various
operating parameters.
Automatic feeder. Indicates whether or not the unit has an automatic
adhesive feeder. See the point ‘Menu 3. Feeding’ for programming the
various operating parameters.
Firing controller. Indicates whether or not the unit has firing controller
functions.