MA-5162-ENG MICRON
+
PISTON ADHESIVE MELTERTECHNICAL CHARACTERISTICS
6-1
6. TECHNICAL CHARACTERISTICS
Generals
Tank capacity
Pumping rate
Melting rate
Number of outputs
Temperature range
(optional)
Temperature control
Max. working pressure (at 6 bar)
Max. installation power (at 230V)
(Maximum current allowed is 27 A
per phase)
External functions
Inputs
Outputs
Electrical requirements
(optional)
Workplace temperature
Dimensions
Weight
(*) Under standard conditions
5,15 liters
29,3 kg/h 7cc/stroke pump (*)
66,0 kg/h 19cc/stroke pump (*)
9,0 kg/h (*)
6 (thread 9/16)
0 to 200°C (32 to 392°F)
230°C (450°F)
RTD ±0.5°C (±1°F)
Pt-100, Ni-120 or NTC-R
81,6 bar (1183 psi)
5.900W (2 outputs)
9.500W (4 outputs)
13.100W (6 outputs)
Unit On-Off / Standby On-Off /
Activity Control / Pumping On-Off /
Communications On-Off / Electrical
Outputs Inhibition.
Low adhesive level / Pumping On /
Temperature OK / Error / Level Not
OK (Warning light).
1N ~ 230V 50/60Hz + PE
3N ~ 400V 50/60Hz + PE
3 ~ 400V 50Hz + PE with
transformer base
0 a 40°C
587 x 341 x 481
587 x 341 x 628 (lid open)
37,5 kg (empty)
9,7 liters
29,3 kg/h 7cc/stroke pump (*)
66,0 kg/h 19cc/stroke pump (*)
13,5 kg/h (*)
6 (thread 9/16)
0 to 200°C (32 to 392°F)
230°C (450°F)
RTD ±0.5°C (±1°F)
Pt-100, Ni-120 or NTC-R
81,6 bar (1183 psi)
6.900W (2 outputs)
10.500W (4 outputs)
14.100W (6 outputs)
Unit On-Off / Standby On-Off /
Activity Control / Pumping On-Off /
Communications On-Off / Electrical
Outputs Inhibition.
Low adhesive level / Pumping On
/ Temperature OK / Error / Level
Not OK (Warning light).
1N ~ 230V 50/60Hz + PE
3N ~ 400V 50/60Hz + PE
3 ~ 400V 50Hz + PE with
transformer base
0 a 40°C
671 x 341 x 481
671 x 341 x 760 (lid open)
45,7 kg (empty)