EasyManua.ls Logo

Meler Micron + 10 - 5 Maintenance; Equipment Cleaning

Default Icon
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MA-5162-ENG MICRON
+
PISTON ADHESIVE MELTERMAINTENANCE
5-1
5. MAINTENANCE
Warning: The melter equipment is equipped with current technology, but
has certain foreseeable risks. Therefore, only allow qualified personnel with
enough training and experience to operate install or repair this equipment.
The following table briefly summarizes the indications for adequate melter
equipment maintenance. Always read the corresponding section carefully.
Equipment cleaning
To continue to take advantage of the melter’s benefits and to ensure the
perfect mobility of its components, it is necessary to keep all its parts clean,
especially the ventilation grate on the upper part of the machine.
Warning: Risk of electric shock. Carelessness may result in injury or death.
Clean the exterior using a cloth moistened with water. Do not use flammable
liquids or solvents.
To carry out external cleaning:
Use cleaning products compatible with polyamide materials.
Apply the cleaning product with a soft cloth.
Do not use sharp tools or scrapers with sharp edges.
Operation Frequency Refer to
External cleaning Daily Equipment cleaning
System depressurization
Before performing maintenance tasks
and repairing the hydraulic system
System depressurisation
Remove electrical cabinet
Before performing pneumatic unit or
pump shaft maintenance
Access to pneumatic unit
Filter cleaning or changing
- As needed (once a year minimum)
- With each adhesive change
Filter maintenance
Emptying and cleaning the tank
- When burnt adhesive is present
- With each adhesive change
Cleaning the tank
Check thermostat operating - Check in continuous work Safety thermostat
Equipment change - Equipment change or repair Remove the equipment from its base

Table of Contents