FOCKE MELER GLUING SOLUTIONS
4-20
MELTER OPERATION
MICRON+ PISTÓN
120 s
ChargeCharge3. Charge
Level alarm
Low level indicator
Sound on alarm
‘3. Load’ Menu
Esta pantalla permite controlar las diferentes cuestiones relativas a la carga
de adhesivo.
Screen 1: Minimum adhesive level sensor
Level alarm. Time after which the unit stops and activates a low-level
alarm.
Minimum level sensor. Activates or deactivates the sensor function.
Sound with alarm: Allows you to configure the sensor alarm to emit a
sound.
MICRON+ PISTÓN
1 s
60 s
90 s
90 s
ChargeCharge3. Charge
Automatic feeder alarm
Sound on alarm
Over charge time
Charge error alarm
Cover opened alarm
Automatic charge
CHARGE
Screen 2: Automatic adhesive feeder
Automatic feeder. Activates or deactivates automatic feeding.
When you press ‘CHARGE’, This lets you activate manual loading. When
pressed, it loads, and when released, the loading stops.
Overfill time: This lets you configure for how much time the adhesive
will continue to be loaded once the lower level sensor has activated (tank
sufficiently full, but not completely full).
Loading error alarm: This defines the maximum amount of time for
filling the tank. If this time is exceeded, the unit displays an alarm.
Open tank lid alarm: An alarm sounds when the tank lid is open and it
stops loading immediately.
Buzzer: This lets you set whether or not loading alarms emit a sound.
MICRON+ PISTÓN
1000 h
1 min
4.4. Statistics
Working hours 4515
2018-05-20 10:45
Filter change
2018-05-20 10:45
RESET
RESET
Datalogger
‘4. Statistics’ Menu
This screen displays:
Hours of operation: This counts all of the hours during which the unit is
in Temperature OK.
To reset the counter to zero, you must press reset.
Filter change. To program a countdown in hours. When it gets to ‘0’, the
unit gives a warning to change the adhesive particles filter.
Once the filter has been changed, press reset to return the counter to the
set value.
Data logger. Time interval for logging the unit’s programming and
operating data.
You can back up this data using the application for PCs.
MICRON+ PISTÓN
120 s
ChargeCharge3. Charge
Level alarm
Low level indicator
Sound on alarm