48 – Control CS 310 / Rev.I 1.55 Control CS 310 / Rev.I 1.55 – 49
12. Technical data
12.1 12.1 Mechanical and electrical dataMechanical and electrical data
Housing dimensions: 215 x 275 x 190 mm
Installation: Fix vertically to the wall
at a minimum height of 1,100 mm
Power supply via
L1, L2, L3, N, PE: 400V/3~ , 50/60Hz
230V/3~ , 50/60Hz
L1, N, PE: 230V/1~ , 50/60Hz
Power input max. 2,200W
for power supply 400V/3~
Fuse protection: 10 A K type
Internal consumption
of the control:
max. 750 mA
Control voltage: 24 V
DC, max. 500 mA; protected by self-
resetting fuse for external sensor systems.
Control inputs: 24 V DCall inputs must be connected so that
they are potential-free.
Minimum signal duration for input control
command > 100 ms
Control outputs: 24 V DC, max. 500 mA
RS485 A and B Only for electronic limit switches
RS485level,terminatedwith120Ω
Safety circuit /
Emergency stop:
All input connections MUST be potential-free;
if the safety circuit is interrupted, no further
electrically powered movement of the operator
is possible, not even in deadman mode
Closing edge
safety device input
(performance level C):
Performance level C
for electrical closing edge safety devices with
8.2kΩterminatingresistorandfordynamic
optical systems
Photocell
(performance level D):
If the photocell is used as a D performance level
protection system, it must be checked at regular
intervals – at least every 6 months – to ensure
that the system is working properly.
MFZ two-wire photocells have a self-test facility,
so this requirement does not apply in this case.
Display (LCD): Only an original MFZ LCD monitor may be used.
Relay outputs: If inductive loads are to be switched (e.g.
additional relays or brakes), these must be
equipped with corresponding interference
suppression measures (e.g. free-wheeling
diodes, varistors, RC elements). Potential-
freenormallyopencontact;min.10mA;
max.230V
AC / 4A.
Once contacts have been used for power
circuits, they can no longer be used for extra-
low current circuits.
Temperature range: Operation: -10°C … +45°C
Storage: -25°C … +70°C
Air humidity: Up to 80% with no condensation
Vibrations: Low-vibration mounting, e.g. on a masonry wall
Protection grade IP 65
Weight approx. 1.8 kg