12. Technical data
12.1 12.1 Mechanical and electrical dataMechanical and electrical data
Housing dimensions: 215 x 275 x 190 mm
Installation: Fix vertically to the wall
at a minimum height of 1,100 mm
Power supply via
L1, L2, L3, N, PE: 400V/3~ , 50/60Hz
230V/3~ , 50/60Hz
L1, N, PE: 230V/1~ , 50/60Hz
Power input max. 2,200W
for power supply 400V/3~
Fuse protection: 10 A K type
Internal consumption
of the control:
max. 750 mA
Control voltage: 24 V
DC, max. 500 mA; protected by self-
resetting fuse for external sensor systems.
Control inputs: 24 V DCall inputs must be connected so that
they are potential-free.
Minimum signal duration for input control
command > 100 ms
Control outputs: 24 V DC, max. 500 mA
RS485 A and B Only for electronic limit switches
RS485level,terminatedwith120Ω
Safety circuit /
Emergency stop:
All input connections MUST be potential-free;
if the safety circuit is interrupted, no further
electrically powered movement of the operator
is possible, not even in deadman mode
Closing edge
safety device input
(performance level C):
Performance level C
for electrical closing edge safety devices with
8.2kΩterminatingresistorandfordynamic
optical systems
Photocell
(performance level D):
If the photocell is used as a D performance level
protection system, it must be checked at regular
intervals – at least every 6 months – to ensure
that the system is working properly.
MFZ two-wire photocells have a self-test facility,
so this requirement does not apply in this case.
Display (LCD): Only an original MFZ LCD monitor may be used.
Relay outputs: If inductive loads are to be switched (e.g.
additional relays or brakes), these must be
equipped with corresponding interference
suppression measures (e.g. free-wheeling
diodes, varistors, RC elements). Potential-
freenormallyopencontact;min.10mA;
max.230V
AC / 4A.
Once contacts have been used for power
circuits, they can no longer be used for extra-
low current circuits.
Temperature range: Operation: -10°C … +45°C
Storage: -25°C … +70°C
Air humidity: Up to 80% with no condensation
Vibrations: Low-vibration mounting, e.g. on a masonry wall
Protection grade IP 65
Weight approx. 1.8 kg

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MFZ Ovitor Control CS 310 and is the answer not in the manual?

MFZ Ovitor Control CS 310 Specifications

General IconGeneral
BrandMFZ Ovitor
ModelControl CS 310
CategoryControl Systems
LanguageEnglish

Related product manuals