Miele CVA610 - Brew Unit - Manual Reset to “Home Position” (Brew Unit not installed in appliance)

Miele CVA610
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
66
CVA610 Coffee System
5.29 Brew Unit – Manual Reset to “Home Position”
(Brew Unit not installed in appliance)
Refer to figure 5-26
3. Press on the latch A; and press the funnel down B.
4. Push the connection piece to the far left position C.
5. Press "PRESS" once.
Figure 5-26: Moving the brew unit to home position.
6. The “home” position (Figure 27) after resetting the Brew Unit.
The Brew Unit can now be reinstalled into the appliance.
Figure 5-27: Brew unit in reset position.