5.30 Brew Unit Creamer Valve - Removal
1. Remove the Brew Unit
2. Remove the output fixing screws.
3. Remove the output.
4. Remove the spring with Creamer Valve.
5.31 Brew Unit Handle - Removal
1. Remove the Brew Unit from the appliance.
2. Press the handle retaining lugs inwards (Figure 5-28).
3. Remove the handle.
Figure 5-28: Brew Unit Highlighting the Output Assembly (Covers the Creamer
Valve) and the Retaining Lugs Securing the Handle to the Assembly.