6. Fault Diagnosis
6.1 Programming Mode
The Programming Mode is available for access by the customer.
The Programming Mode allows various options and / or features to
configured.
To access the Programming Mode, simply turn the selector knob to
the “Program Mode” position
Language
German, Dutch, Portuguese, Spanish, English,
Italian or French
Rinsing
on, off
Water hardness
hardness levels 1 to 4
Temperature long coffee
minimum, low, medium, high, maximum
Temperature coffee
minimum, low, medium, high, maximum
Temperature short
(espresso) coffee
minimum, low, medium, high, maximum
Pre-brewing
on, off,
Pre-grinding
off, on
Program hot water
off, on
Total coffee
number of coffee servings
Descaling
automatic descaling program
Standby timer
to put unit in, selectable in 15 minute periods
Table 5-1: Programming Mode