OM-225 389 Page 19
3-7. Factory-Set Parameter Defaults And Range And Resolution
Parameter Default Range And Resolution
PROCESS TIG HF TIG HF, STICK
A MAIN / PEAK
AC
DC
150 A
150 A
5 200 Amps
5 200 Amps
PULSER
PPS
PEAK t
BKGND A
Off
10 PPS
50%
50%
ON / OFF
0.115 PPS
20 80 Percent
5 95 Percent
POSTFLOW Auto
Manual:
5 - 50 Amps: 5 Seconds
51 - 200 Amps: Adds 1 Second Per 10 Amps
1 -25 Seconds
DIG 30% 0 100 Percent
BALANCE 7 110
TIG HF Syncro-Startt Settings
AC
DC
Med
Med
Soft/Med/Hot
Soft/Med/Hot