OM-284794 Page 34
F
Complete Parts List is available at www.MillerWelds.com
7-2. Summary Of Default And Pro-Set Parameters
AC TIG DC TIG DC PULSE TIG STICK
Process Menu
Range
Default
(Pro-Set)
Range
Default
(Pro-Set)
Range
Default
(Pro-Set)
Range
Default (Pro-
Set)
[BAL]
Balance
Ball 30%,
60% to 80%
68% — — — — — —
[FREQ]
Frequency
50-150 HZ 70 HZ — — — — — —
[PPS] Pulses
Per Second
— — — —
0.1 to 150
PPS
100 PPS — —
[POST]
Post Flow
Auto, Off,
On 1 to 50
Seconds
Auto
Auto, Off,
On 1 to 50
Seconds
Auto
Auto, Off,
On 1 to 50
Seconds
Auto — —
[DIG]
Dig Control
— — — — — — Off to 100% 30%
User Menu
Range Default Range Default Range Default Range Default
[STRT]
Start Method
HF, Lift HF HF, Lift HF HF, Lift HF — —
[TUNG]
Tungsten Size
0.40 to 1/8 3/32 0.40 to 1/8 3/32 0.40 to 1/8 3/32 — —
[RMT]
Trigger Mode
2T, On*,
Standard
2T
2T, On*,
Standard
2T
2T, On*,
Standard
2T
On,
Standard
ON
[PRE]
Pre Flow
Off,
0.2 to 25
Seconds
0.2 Seconds
Off,
0.2 to 25
Seconds
0.2
Seconds
Off,
0.2 to 25
Seconds
0.2
Seconds
— —
Tech Menu
Range Default Range Default Range Default Range Default
[ARC] [T/CY]
Arc Timer
— — — — — — — —
[ERR] [LOG]
Error Log
— — — — — — — —
[COOL]
Cooler Power
Auto, On,
Off
Auto
Auto, On,
Off
Auto
Auto, On,
Off
Auto
Auto, On,
Off
Auto
[MACH] [RESET]
Machine Reset
— — — — — — — —
[SOFT] [WARE]
Software Number
— — — — — — — —
[SERL] [NUM]
Serial Number
— — — — — — — —
* “On” Trigger Mode only available in Lift Arc Start Method.