EasyManua.ls Logo

Miller syncrowave 300 - Summary of Default and Pro-Set Parameters

Miller syncrowave 300
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OM-284794 Page 34
F
Complete Parts List is available at www.MillerWelds.com
7-2. Summary Of Default And Pro-Set Parameters
AC TIG DC TIG DC PULSE TIG STICK
Process Menu
Range
Default
(Pro-Set)
Range
Default
(Pro-Set)
Range
Default
(Pro-Set)
Range
Default (Pro-
Set)
[BAL]
Balance
Ball 30%,
60% to 80%
68%
[FREQ]
Frequency
50-150 HZ 70 HZ
[PPS] Pulses
Per Second
0.1 to 150
PPS
100 PPS
[POST]
Post Flow
Auto, Off,
On 1 to 50
Seconds
Auto
Auto, Off,
On 1 to 50
Seconds
Auto
Auto, Off,
On 1 to 50
Seconds
Auto
[DIG]
Dig Control
Off to 100% 30%
User Menu
Range Default Range Default Range Default Range Default
[STRT]
Start Method
HF, Lift HF HF, Lift HF HF, Lift HF
[TUNG]
Tungsten Size
0.40 to 1/8 3/32 0.40 to 1/8 3/32 0.40 to 1/8 3/32
[RMT]
Trigger Mode
2T, On*,
Standard
2T
2T, On*,
Standard
2T
2T, On*,
Standard
2T
On,
Standard
ON
[PRE]
Pre Flow
Off,
0.2 to 25
Seconds
0.2 Seconds
Off,
0.2 to 25
Seconds
0.2
Seconds
Off,
0.2 to 25
Seconds
0.2
Seconds
Tech Menu
Range Default Range Default Range Default Range Default
[ARC] [T/CY]
Arc Timer
[ERR] [LOG]
Error Log
[COOL]
Cooler Power
Auto, On,
Off
Auto
Auto, On,
Off
Auto
Auto, On,
Off
Auto
Auto, On,
Off
Auto
[MACH] [RESET]
Machine Reset
[SOFT] [WARE]
Software Number
[SERL] [NUM]
Serial Number
* “On” Trigger Mode only available in Lift Arc Start Method.