Chapter5 Troubleshooting
5-7
1
2
2
2
5
6
Errors when performing operations
Please set the ext.heater to the correct
position
Check the position of the extension heater.
(make sure to set correct vertical position,
and not set in halfway position)
Display Cause Measures
Invalid Operation
!Cover Open
The function cannot be executed
because the cover is open.
Execute the operation after closing the
cover.
Invalid Operation
!Media Undetected
Operation cannot be performed because
no media is detected.
Execute after media is detected.
Invalid Operation
!No Media
Operation cannot be performed because
media is not set.
Invalid Operation
!Data Remain
The function cannot be executed
because the data is being received.
Execute the operation after executing data
clear.
Invalid Operation
Check Waste Ink
Since the count of the waste ink tank
exceeds the specified amount (80%), the
function cannot be executed.
Replace the waste ink tank, execute the
function after count reset.
Invalid Operation
!Ink Error
The function cannot be executed
because an ink error has occurred.
Execute the function after replacing the ink
pack or 10kg ink tank and ink IC chip.
INK NEAR END
1_ _ _ _ _ _ _
The function cannot be executed
because an ink near-end has occurred.
(Routes with UISS are displayed when
both inks are near-ended.)
Invalid Operation
!Connect 10kg Supply Unit
10kg The function cannot be executed
because the supply unit is not con-
nected.
Restart the unit.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
Invalid Operation
Take-up LimitDetect
The function cannot be executed, since
the upper limit of the take-up tension bar
position is detected.
Lower the take-up tension bar and then exe-
cute the function.
Invalid Operation
Feeding LimitDetect
The function cannot be executed, since
the upper limit of the feeding tension bar
position is detected.
Execute the function after lowering the feed-
ing tension bar.
Invalid Operation
Take-up Wrong
The function cannot be executed, since
the take-up tension bar is not moving
from the lower limit position.
Execute the function after confirming that the
take-up unit operates properly with the jog
key.
Invalid Operation
Feeding Wrong
The function cannot be executed, since
the feeding tension bar is not moving
from the lower limit position.
Execute the function after confirming that the
take-up unit operates properly with the jog
key.
Invalid Operation
Take-up CoverOpen
The function cannot be executed
because the cover of take-up unit is
open.
Execute the operation after closing the cover
of take-up unit.
Invalid Operation
Feeding CoverOpen
The function cannot be executed
because the cover of feeding unit is
open.
Execute the operation after closing the cover
of feeding unit.