Chapter5 Troubleshooting
5-11
1
2
2
2
5
6
Error message
When an error message is displayed, eliminate the error according to the chart below.
When displaying again, contact your dealer or an office of MIMAKI to call for service.
SubtankSens
Sub tank sensor value cannot be
detected normally.
• Restart the machine.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
TankLevel H Even when ink is consumed, the amount
of ink in the sub tank is not reduced.
• Failure occurs in ink suction.
• A lot of nozzle clogging has occurred.
• Restart the machine.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
TankLevel L
Supply Ink
The specified amount of ink was not
supplied (semi-auto / manual) with 10 kg
ink supply.
• Check that there is sufficient ink in the 10kg
ink tank.
• Check that the ink supply pipe is properly set
in the 10kg ink tank.
• Execute 10kg ink supply (semi-auto / man-
ual).
If displaying again, contact your local distrib-
utor, our sales office, or service center.
!Ink Remaining
Need to check because the remaining
amount of the tank has become a little
left. (The remaining ink level in the tank
is less than 25%.)
• Perform ink level correction as necessary.
Display Cause Measures
ERROR 108
HD THERMIS[1234]
An error occurred in the head tempera-
ture control.
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
ERROR 108
HD CONNECT[1234]
An error occurred in the connection of
the head.
ERROR 122
CHECK:SDRAM
An error occurred in the SDRAM.
ERROR 128
HDC FIFO OVER
An error occurred in the head control
PCB.
ERROR 128
HDC FIFO UNDER
ERROR 129
BATTERY EXCHANGE
Detected battery exhaustion in internal
clock.
• Contact your local distributor, our sales
office, or service center.
ERROR 12a
HDC SPEED
Detected an error in the waveform for
the printing.
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
ERROR 130
HD DATA SEQ
ERROR 146
E-LOG SEQ
A sequential number error occurred in
the event log.
ERROR 151
Main PCB V1R2
An error occurred in the power supply
system of the main PCB.
ERROR 152
Main PCB V2R5
ERROR 153
Main PCB V3R3
ERROR 154
Main PCB V05
ERROR 157
Main PCB VTT
ERROR 16e
Main PCB V3R3B
ERROR 15f
HEAD DRIVE HOT
Display Cause Measures