Loading...
Refill antifreeze liquid
4-30
Refilling antifreeze liquid
If a lack of water error is displayed, refill antifreeze liquid-mixed water.
To fill with the water, refill about 200cc.
1
Mix antifreeze liquid with water.
(1) Mix 1 part antifreeze liquid with 2 parts water.
(2) Put the mixed water into a provided syringe.
2
Uncover the feed-water inlet and the air
vent.
The feed-water inlet is on the left side of the water
heating device, and the air vent is on the bottom of
the water heating device.
3
Refill antifreeze liquid.
Fill the antifreeze liquid from the feed-water inlet.
Fill it up seeing the water gauge on the back of this
machine.
Displaying red on the water gauge indicates full.
4
Cover the feed-water inlet and the air
vent.
feed-water
inlet
air vent cover
water gauge