3-4
Checking UV ink curing level
Deteriorating of the UV LED may lower the ink curing level.
Check the ink curing level and adjust the UV LED light intensity as needed.
1
Set a media for drawing pattern.
2
When <LOCAL> is displayed, press the
key.
3
Select [HARDEN CHECK] with the
key, and press the key.
4
Select resolution with the
key, and press the key.
• Setting value : 300 x 300 dpi, 600 x 300 dpi, 600 x 600 dpi, 600 x 900 dpi, 1200 x 600 dpi,
1200 x 900 dpi, 1200 x 1200 dpi
5
Select drawing quality with the
key, and press the key.
• Options : STANDARD, FINE, FAST
6
Select the scan direction with the
key.
• Options : Y Si, Y Re, Y Bi
7
Press the key.
• Test drawing starts.
• If the temperature of the water heating device has not reached the predetermined value, a
message appears. In this case, it is not drawn. When the display disappears, drawing can be
started.