MPPS Preset
MPPS setting items are described as follows:
TIP:
Set the MPPS service as the default when using the MPPS.
Storage Commitment Setting
DICOM storage commitment setting items are described as follows:
TLS Transport Layer Security. Select whether to encrypt the data during
network transportation.
Strategy Name Select the preset DICOM strategy.
Remove Attributes (0) Preset what DICOM elements that will not be used in worklist query.
Item Description
Item Description
Device Name After you set the server (s) in DICOM Server Setting, the name (s) will
appear in the drop-down list, select the name of the MPPS server.
Service Name Default is server-MPPS, and it can be modified.
AE Title Application Entity title. It should be consistent with that of the MPPS
server.
Port DICOM communication port, 104 by default. The port should be
consistent with that of the MPPS server.
Maximum Retries It starts retrying if it fails to send DICOM task to the server. The retry
entry times should be this value.
Interval Time(s) Reserved feature.
Timeout Refers to the amount of time after which the system will stop trying to
establish a connection to the service.
Name NOTE
Device Name After you set the server (s) in DICOM Server Setting, the name (s) will
appear in the drop-down list, select the name of the storage commitment
server.
DICOM Service Name Default is server-SC, and it can be modified.
AE Title Application Entity title. Here, it should be consistent with that of the
storage commitment server.
Port DICOM communication port, 104 by default. Here, the port should be
consistent with that of the storage commitment server port.
Maximum Retries Reserved feature.
Interval Time(s) Reserved feature.
Timeout Refers to the amount of time after which the system will stop trying to
establish a connection to the service.
Associated Storage
Service
The associated storage server is preset before storage commitment, only
after the exam is sent out, can storage commitment be created.

Table of Contents

Other manuals for Mindray TEX20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray TEX20 and is the answer not in the manual?

Mindray TEX20 Specifications

General IconGeneral
BrandMindray
ModelTEX20
CategoryDiagnostic Equipment
LanguageEnglish

Related product manuals