4 - 14 Operator’s Manual
4 Setup
2-dimension barcode reader (2D)
General Analysis Mode
Select “General” from “Analysis Mode” drop-down list: The scan codes consist of Patient ID,
Other ID, Patient Name, Birth, etc.
Append Options The information of operator or diagnostician can be appended after selecting
the check box.
For example, after scanning a 1D barcode of an operator or diagnostician, the
obtained data is A, and A will be displayed in “Operator” or “Diagnostician”
item in Patient page automatically.
After scanning a 1D barcode of an operator or diagnostician for a second
time, the obtained data is B, and A will be appended by B in “Operator” or
“Diagnostician” item in Patient page automatically.
Default Item If the default item is set to “No”, and both the 2D and 1D barcodes fail to be
matched, the obtained data of the barcode is input as a string of characters.
After selecting a default item from the drop down list of “Default Item”, the
obtained data of the scanned barcode will be displayed in the corresponding
selected default item.
For example, if the default item is set to “Patient ID”, and both the 2D and
1D barcodes fail to be matched, the obtained data is displayed in the “Patient
ID” item in Patient page automatically.
Service Query Select a service query. For example, select “Worklist server” from the
drop-down list, and the system searches the Worklist server according to
the scanned data.
Select “No” from the drop-down list, and the system creates a new exam
in the Patient page according to the scanned data.
Default Query
Item
Select a default item for searching the service query.
For example, users select “Patient ID” from the drop down list of
“Worklist Default”, and the system searches Patient ID in the Worklist
server.
Select “No”, and the system searches the Worklist server in the priority
order: “Patient ID” > “Last name” > “Accession #”.
NOTE:
The matching priority order is 2D item, 1D item, and Default Item, after
the 1D/2D and default items are configured.
Import/Export Import and export configuration files to preset the barcode. For details,
please contact the service engineer.
Item Description
Item Description
Scan Barcode Example Input a barcode example, barcode example is separated by separators
(the separator is used to set the start and end position of each item), and
the barcode data is displayed in the following items in turn.

Table of Contents

Other manuals for Mindray TEX20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray TEX20 and is the answer not in the manual?

Mindray TEX20 Specifications

General IconGeneral
BrandMindray
ModelTEX20
CategoryDiagnostic Equipment
LanguageEnglish

Related product manuals