5-20 Mx-Series Manual
11202
Vision frame
information error
If an error occurs, make sure to contact
the C/S engineer and to capture the
screen.
11203
Invalid inspection
area
If an error occurs, make sure to contact
the C/S engineer and to capture the
screen.
Error Code
Message Description
Actions
References
11204
Tolerance error
Check the tolerance stored in the
component DB. Permitted range is
0~100. Typically, the range is 10~30.
11205
Inspection centering
error
If an error occurs, make sure to
contact the C/S engineer and to
capture the screen.
11211
Threshold result error
Check illumination or contamination
on the lower surface of the
component and retry inspection. If
the error is not resolved, contact the
C/S engineer.
11212
Fail in initial component
area inspection
Check illumination, contamination of
the component or background and
component DB information and retry
inspection.
11213
The result of the initial
component area
inspection exceeds the
inspection area.
Check illumination, contamination of
the component or background and
component DB information and retry
inspection.
11214 -
11217
The result of
component area
inspection exceeds
the inspection area.
(Up, down, left, right)
Check the offset from the center of
component and adjust the picking
position.
11218
The result of component
area inspection exceeds
the inspection area.
(Ball)
Check the offset from the center of
component and adjust the picking
position.
11219
Inspection angle
calculation error
Check illumination, contamination of
the component or background and
component DB information and retry
inspection.
11221 -
11224
The result of component
inspection (square)
exceeds the inspection
area. (Up, down, left,
right)
This error occurs when the result of
component inspection exceeds the
defined inspection range. Set the
component picking position to the
center of the component.

Table of Contents