Vision frame
information error
If an error occurs, make sure to contact
the C/S engineer and to capture the
screen.
If an error occurs, make sure to contact
the C/S engineer and to capture the
screen.
Check the tolerance stored in the
component DB. Permitted range is
0~100. Typically, the range is 10~30.
Inspection centering
error
If an error occurs, make sure to
contact the C/S engineer and to
capture the screen.
Check illumination or contamination
on the lower surface of the
component and retry inspection. If
the error is not resolved, contact the
C/S engineer.
Fail in initial component
area inspection
Check illumination, contamination of
the component or background and
component DB information and retry
inspection.
The result of the initial
component area
inspection exceeds the
inspection area.
Check illumination, contamination of
the component or background and
component DB information and retry
inspection.
The result of
component area
inspection exceeds
the inspection area.
(Up, down, left, right)
Check the offset from the center of
component and adjust the picking
position.
The result of component
area inspection exceeds
the inspection area.
(Ball)
Check the offset from the center of
component and adjust the picking
position.
Inspection angle
calculation error
Check illumination, contamination of
the component or background and
component DB information and retry
inspection.
The result of component
inspection (square)
exceeds the inspection
area. (Up, down, left,
right)
This error occurs when the result of
component inspection exceeds the
defined inspection range. Set the
component picking position to the
center of the component.