EasyManuals Logo

Mitel 3000 Installation And Maintenance Manual

Mitel 3000
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
Mitel 3000
Installation & Maintenance Manual
111
DID Line Type - Service Types
For DID Line Types the following options are available: -
None - No Service Type is set.
ANI
DNIS
*ANI*
*DNIS*
*ANI*DNIS*
1. From the programming extension, press the PROGRAM key.
2. Press the Scroll Down key () until “System Programming” is displayed.
3. Select “System Programming”.
4. Enter the System Programming Password and select “Lines”.
5. Press the Scroll Down key () until “T1 (RBS) or PRI (ISDN)” is displayed.
6. Select T1 (RBS).
7. Select “Line Type”.
8. Select “DID” line type.
9. Select one of the options listed above.
The default setting is “None”.
Loop Start Line Type - Service Types
For Loop Start Line types the following options are available: -
None - No Service Type is set.
Caller ID.
1. From the programming extension, press the PROGRAM key.
2. Press the Scroll Down key () until “System Programming” is displayed.
3. Select “System Programming”.
4. Enter the System Programming Password and select “Lines”.
5. Press the Scroll Down key () until “T1 (RBS) or PRI (ISDN)” is displayed.
6. Select T1 (RBS).
7. Select “Line Type”
8. Select “Loop Start” line type.
9. Select one of the options listed above.
The default setting is that no service type is set.
Ground Start Line Type - Service Types
If Ground Start is selected no additional menu is presented. There are no services available on Ground Start lines.
Programming the Start Types
The start types can be set as Immediate, Wink, Delay Dial or Dial Tone depending on the line type.
E&M Start Types
When E&M Service Type is selected four Start Types are available.
Immediate.
Wink.
Delay Dial.
Dial Tone.
1. Enter the System Programming Password and select “Lines”.
2. Press the Scroll Down key () until “T1 (RBS) or PRI (ISDN)” is displayed.
3. Select T1 (RBS).
4. Select “E&M”.
5. Select the service type.
6. The list of Start Types is presented, select the required Start Type. (Default setting is Wink Start)

Table of Contents

Other manuals for Mitel 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitel 3000 and is the answer not in the manual?

Mitel 3000 Specifications

General IconGeneral
BrandMitel
Model3000
CategoryTelephone System
LanguageEnglish

Related product manuals