Mitel 3000
Installation & Maintenance Manual
48
Hot swapping faulty modules
The CO Line Modules can be replaced without powering the system down.
The CO Line Modules can be removed and replaced without powering down the system.
The Expansion Modules cannot be removed and replaced without powering down the system.
The Voice Module can be removed and replaced without powering down the system.
When a Voice module is replaced, all recorded messages and greetings are lost. If a
Voice module is removed and reinserted, the messages and greetings are retained.
The Broadband Module cannot be removed and replaced without powering down the system.
The T1/E1 PRI Module can be removed and replaced without powering down the system.
If there are calls in progress on a PRI Interface when the T1/E1 PRI Module is
reinserted it can take up to 90 seconds for the network to return the line to service.