Operation and Maintenance
Code Name Error description Error handling
51 DL 04 Expiry Timer (on cordless
phone) has expired
Try again
70 Timer Expired MM timer in system
has expired (during
registration)
Try again
44 Failure to set up traffic
bearer
Connection cannot be
set up as too many
cordless phones are
phoning within the
same range
• Try again
• If still unsuccessful after
several attempts, restart
cordless phone and try
again.
45 No Quiet Channel No channel available,
same as code 44
Same measures as for code
44
80 Reject Location Area.
Not allowed. Misused to
indicate wrong "design"
version.
Wrong mode during
logon.
Logon to the system lt; I5
• Office 135: Longclick
"Home"
Logon to the system > I5:
• Office 135: Shortclick
"Home"
6.5.3 Other aids
6.5.3.1 System logs
During operation or in the event of a malfunction the communication server stores the current operating
data in the file system in the directory /home/mivo400/logs.
You can open, view and back up these log files on any storage device, in WebAdmin in the System logs
view.
6.5.3.2 File system state
In the File system state view you can see the thematically structured file system's memory load. In an AIN
the file systems for all nodes can be viewed.
Release 7.1
269 System Manual for Mitel SMB Controller