Installation
Warning:
Failure to observe the location requirements can cause the communication server to overheat,
damaging electrical components and/or the surrounding area.
An event message is generated if the heat dissipation is insufficient. Appropriate measures must
be taken immediately to improve the heat dissipation, e.g. by providing the required clearances or
lowering the ambient temperature.
Table 28: Location requirements
Heat radiation • Do not position in direct sunlight, near radiators or near
other heating sources
EMC • Do not position in strong electromagnetic fields of
radiation(e.g.near x-ray equipment, welding equipment
or similar).
Heat dissipation • Do not place any objects on top of the communication
server.
• Observe the clearance requirements for wall mounting
and desktop installation (see Minimum distances for
wall mounting (front panel facing to the right) and
Minimum distances for wall mounting (front panel facing
downwards)).
• In a rack-mounted installation the space to the left and
right between the communication server and the wall of
the 19” rack must remain empty.
Environment • Ambient temperature 5 °C...45 °C
• Relative humidity 30…80%, non-condensing
4.2.4 Safety regulations
Be sure to observe the following safety regulations before carrying out work inside a communication
server: