DC powered base units
The DC power type base units have restrictions in expandable I/O points since they lack a
built-in service power supply.
The following matrixes show the expandable units up to the mark, where the desired inputs
(horizontal axis) and outputs (vertical axis) intersect. System are expandable up to the mark
when the supply voltage is 16.8 V to 19.2 V.
For FX
3U-16MR/DS, FX3U-16MT/DS, FX3U-16MT/DSS, FX3U-32MR/DS, FX3U-32MT/DS or
FX
3U-32MT/DSS:
Example
When adding 16 inputs to a DC powered base unit with 16 or 32 I/O, a maximum of 32 out-
puts are expandable. When adding 16 inputs under the supply voltage 16.8 V to 19.2 V, a
maximum of 16 outputs are expandable.
For FX
3U-48MR/DS, FX3U-48MT/DS, FX3U-48MT/DSS, FX3U-64MR/DS, FX3U-64MT/DS,
FX
3U-64MT/DSS, FX3U-80MR/DS, FX3U-80MT/DS or FX3U-80MT/DSS:
Example
When adding 32 inputs to a DC powered base unit with 48, 64, or 80 I/Os, a maximum of 40
outputs are expandable. But when adding 32 inputs under the supply voltage 16.8 V to
19.2 V, a maximum of 24 outputs are expandable.
System Configuration The Hardware
2-40 MITSUBISHI ELECTRIC
0 8 16 24 32
24
16
8
-0
40
32
40 48 56 64
Number of additional inputs
Number of additional
outputs
see example
Not allowed to add
쎲쑗
쑗쑗
쎲쎲
쎲쎲쎲쑗쑗
16
8
-0
32
24
40
48
0 8 16 24 32 40 48 56 64
72 80 88 96
56
64
Number of additional inputs
Number of additional
outputs
see example
쎲쎲
쎲쑗
쑗쑗
쎲쎲
쎲쎲쑗
쎲쎲쎲
쎲쎲쑗쑗
쎲쎲 쎲쎲쎲쎲
Not allowed to add