M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.8 Operation Panel I/O Unit
77
IB-1501613-A
<Input conditions>
Set the input signal within the range as shown in the conditions below.
[FCU8-DX731/FCU8-DX750/FCU8-DX760/FCU8-DX761]
[FCU8-DX834]
(*1) Input signal holding time: The guide is 40 ms or more. The input signal is recognized only when its "ON" state is held lon-
ger than the ladder processing cycle time.
(E): External signal, (I): Internal signal
Set the number of DI points that are simultaneously turned ON to be less than half of the total points.
If many points are set to be simultaneously turned ON, operation panel I/O unit may be deteriorated due to the heat.
24 V common 0 V common
1 Input voltage at external contact ON 6 V or less 18 V or more, 25.2 V or less
2 Input current at external contact ON 5 mA or more
3 Input voltage at external contact OFF 20 V or more, 25.2 V or less 4 V or less
4 Input current at external contact OFF 1.2 mA or less
5 Input resistance 3.3 kΩ
6 Tolerable chattering time (T1) 3 ms
7 Input signal holding time (T2) 40 ms or more (*1)
8 Input circuit operation delay time (T3 and T4) 3 ms to 16 ms
9 Machine side contact capacity 30 V or more, 16 mA or more
24 V common 0 V common
1 Input voltage at external contact ON 6 V or less 18 V or more, 25.2 V or less
2 Input current at external contact ON 3 mA or more
3 Input voltage at external contact OFF 20.2 V or more, 25.2 V or less 3.8 V or less
4 Input current at external contact OFF 0.7 mA or less
5 Input resistance 5 kΩ
6 Tolerable chattering time (T1) 3 ms
7 Input signal holding time (T2) 40 ms or more (*1)
8 Input circuit operation delay time (T3 and T4) 3 ms to 16 ms
9 Machine side contact capacity 30 V or more, 16 mA or more
Connection to 24 V common input Connection to 0 V common input
T1T1
T2
GND
+24V
T4T3
(E)
(I)
T1T1
T2
T4T3
GND
+24V
(E)
(I)
Note

Table of Contents