14
14-33
Inspection procedure
Inspection: Thermostat
Stir the water using a stirring rod to maintain an even water tem-
perature in the container, then conduct the tests indicated below.
If the measured values deviate from the standard value ranges,
replace the thermostat.
(1) Valve opening temperature
Hold the thermostat with wire to keep it away from the heat
source.
Heat the water gradually to the valve opening temperature.
Maintain this temperature for five minutes and make sure that
the valve is completely open.
Make sure that the valve closes completely when the water tem-
perature drops below 65°C.
(2) Valve lift
Heat the water to a temperature slightly higher than the valve
opening temperature. Maintain this temperature for five minutes
and measure the valve lift.
Installation procedure
Installation: Gasket
Fit the gasket onto the thermostat case in the illustrated direc-
tion.